Fix Finder
What’s the problem?
Household
61 fixes
Why does my VFD trip on ground fault only during motor startup
A VFD that trips on ground fault only during startup usually indicates insulation breakdown in the motor windings or cables that only…
See the fixWhy does my VFD trip on overcurrent during acceleration?
A VFD trips on overcurrent during acceleration usually because the motor demands more current than the drive's limit, often due to too-fast…
See the fixWhy does my VFD trip on overcurrent fault during motor acceleration
A VFD trips on overcurrent during acceleration when the motor draws more current than the drive's limit, usually caused by too-short acceleration…
See the fixWhy does my VFD trip on overcurrent fault during motor startup?
A VFD trips on overcurrent at startup usually because the motor draws excessive inrush current, the acceleration ramp is too short, or…
See the fixWhy does my VFD trip on overvoltage when the motor decelerates?
A VFD trips on overvoltage during deceleration because the motor acts as a generator, pushing energy back into the DC bus faster…
See the fixWhy does my VFD trip on overvoltage when the motor slows down?
Your VFD trips on overvoltage during deceleration because the motor acts like a generator and pumps energy back into the drive, spiking…
See the fixWhy does my VFD-driven motor vibrate and overheat at low speeds below 20 Hz?
A VFD-driven motor vibrating and overheating at low speeds usually means the VFD's carrier frequency is too low, the motor isn't rated…
See the fixWhy does my VFD-driven pump motor trip on overcurrent at low speeds?
A VFD-driven pump motor tripping on overcurrent at low speeds usually means the VFD's torque boost or voltage/frequency ratio is set too…
See the fixWhy is a three-phase motor humming but not starting?
A three-phase motor that hums but won't start usually has one phase lost (single-phasing), a bad start capacitor if it's a single-phase…
See the fixWhy is my conveyor motor tripping the breaker under load?
Your conveyor motor is tripping the breaker under load most often because it is drawing too much current — from a jammed…
See the fixWhy is my hydraulic pump running hotter than usual?
Your hydraulic pump usually runs hot because the system is fighting extra resistance or losing cooling: a clogged filter, low oil, wrong-viscosity…
See the fixWhy is my industrial air compressor drawing more current than its nameplate rating?
Your compressor is pulling excess current because the motor windings are degrading, the intake filter is clogged, or the unloader valve is…
See the fix